Novus Biologicals products are now on bio-techne.com

Lightning-Link® Rapid Cy3 Antibody Labeling Kit

Images

 
Lightning-Link Rapid Cy3 Antibody Labeling Kit [340-0010]

Product Details

Summary
Conjugate
Cy3
Format
Cy3 (A=553, E=569)
Kit Type
Antibody Labeling Kit

Order Details

Novus Biologicals is part of Bio-Techne

Shop this product on bio-techne.com

Lightning-Link® Rapid Cy3 Antibody Labeling Kit Summary

Description
Lightning-Link Rapid is an innovative technology that enables direct labeling of proteins, peptides or other biomolecules for use in R&D applications, drug discovery and the development of diagnostic kits (See protocol for further information.

The easy-to-use, one step procedure allows researchers to covalently label biomolecules with only 30 seconds hands-on time; furthermore conjugates are ready to use in less than twenty minutes.

The researcher simply pipettes the biomolecule into a vial of lyophilized mixture containing the label of interest and incubates (for more details please watch the video below).

FeaturesBenefits
Quick and easy to useSave time, no special knowledge required
No separation steps100% recovery - no antibody/protein loss
Can be used in a wide range of applicationsFlexible
Freeze driedShips at ambient temperature, long shelf-life
Fully scalable (10 ug to 1 g or more)Easy transfer from R&D to manufacturing
Stringently QC testedConsistent high quality, excellent batch-to-batch reproducibility
Large number of labels available Experimental flexibility
Reliable: nearly 300 referencesSuccessfully used in many fields of research


Cyanine Dye 3 (Cy3) has a strong absorption peak at 552nm. The maximum emission peak is at 576nm, with an excitation coefficient of 1.5 x105 cm-1 M-1. Cy3 can be used as an alternative to Alexa Fluor 555, DY-550, Rhodamine Red-X and TAMRA [5(6)-Carboxytetramethylrhodamine].

Cyanine dyes are bright and stable fluorescent dyes

Learn more about Lightning-Link™ Conjugation Kits by reading FAQs

For more information please check out these useful links!
Antibody Labeling Guide
Antibody Conjugation Illustrated Assay

Kit Type
Antibody Labeling Kit

Applications/Dilutions

Application Notes
By circumventing the desalting or dialysis steps that commonly interrupt traditional antibody conjugation procedures, LightningLink technology can be used to label both small (e.g. 10 ug) and large quantities of primary antibodies with ease. Batch-to-batch variation upon scale up is minimal as the process is so simple, and recoveries are always 100%.
Publications
Read Publications using 340-0010.

Packaging, Storage & Formulations

Storage
Store at -20C.

Kit Components

Components
  1. 1 or 3 glass vial(s) of Lightning-Link Rapid mix
  2. 1 vial of LL-Rapid Modifier reagent
  3. 1 vial of LL-Rapid Quencher reagent

Notes

This product is manufactured by Abcam and distributed by Novus Biologicals.

This product is for research use only and is not approved for use in humans or in clinical diagnosis. This product is guaranteed for 1 year from date of receipt and this statement overrides any mentioned guarantee period on the limitations section of this products datasheet. Please contact technical@novusbio.com with questions.

Background

Lightning-Link® Rapid Antibody Labeling kits

Limitations

This product is for research use only and is not approved for use in humans or in clinical diagnosis. Kits are guaranteed for 6 months from date of receipt.

Publications for Lightning-Link (R) Rapid Cy3 Kit (340-0010)(8)

We have publications tested in 3 applications: ELISA, FLOW, ICC/IF.


Filter By Application
ELISA
(1)
FLOW
(2)
ICC/IF
(1)
All Applications
Filter By Species
All Species
Showing Publications 1 - 8 of 8.
Publications using 340-0010 Applications Species
Hatterer E, Barba L, Noraz N et al. Co-engaging CD47 and CD19 with a bispecific antibody abrogates B-cell receptor/CD19 association leading to impaired B-cell proliferation. MAbs 2018-12-19 [PMID: 30569825]
Naz N, Jimenez AR, Vilaplana AS et al. Neonatal hydrocephalus is a result of a block in folate handling and metabolism involving 10 formyl tetrahydrofolate dehydrogenase. J. Neurochem. 2016-06-13 [PMID: 27294849] (ELISA) ELISA
Chan CY, Zhao H, Pugh RJ et al. Purinosome formation as a function of the cell cycle. PNAS 2015-01-01 [PMID: 25605889]
Zhao H, Chiaro CR, Zhang L et al. Quantitative Analysis of Purine Nucleotides Indicates Purinosomes Increase de Novo Purine Biosynthesis. J Biol Chem. 2015-01-01 [PMID: 25605736] (ICC/IF) ICC/IF
van Dam A, Aalders MC, van de Braak K et al. Simultaneous labeling of multiple components in a single fingermark. Forensic Sci Int 2013-01-01 [PMID: 24053878]
Cayer MP, Samson M, Bertrand C et al. Suppression of protein phosphatase 2A activity enhances Ad5/F35 adenovirus transduction efficiency in normal human B lymphocytes and in Raji cells. J Immunol Methods. 2011-01-01 [PMID: 22210093] (FLOW) FLOW
Arcand J, Robitaille G, Koenig M et al. Heparin inhibits the interaction of DNA topoisomerase I (topo-I)/anti-topo-I immune complexes with heparan sulfate on dermal fibroblasts. Arthritis Rheum. 2011-01-01 [PMID: 22095242] (FLOW) FLOW
Samson M, Jung D. Intracellular trafficking and fate of chimeric adenovirus 5/F35 in human B lymphocytes. J Gene Med 2011-01-01 [PMID: 21766397]

Reviews for Lightning-Link (R) Rapid Cy3 Kit (340-0010) (0)

There are no reviews for Lightning-Link (R) Rapid Cy3 Kit (340-0010). By submitting a review you will receive an Amazon e-Gift Card or Novus Product Discount.
  • Review with no image -- $10/€7/£6/$10 CAD/¥70 Yuan/¥1110 Yen
  • Review with an image -- $25/€18/£15/$25 CAD/¥150 Yuan/¥2500 Yen

FAQs for Lightning-Link (R) Rapid Cy3 Kit (340-0010). (Showing 1 - 10 of 11 FAQs).

  1. Can I label a peptide/protein/antibody other than IgG?
    • Yes. The Lightning-Link® technology works by targeting free amine groups on your target, meaning it can be used to label most biomolecules.As the protocols provided were optimized for labeling IgGs, we would recommend you adjust the amount of material you add to the Lighting-Link® vial to allow for molecular weight difference. This should be done without changing the volume added to the vial, as this could affect the conjugation efficiency. As a rough guideline, we would recommend changing the amount of material proportionally to the size difference with IgGs. An average IgG is about 160kD, therefore for a target that is half the size of an antibody (about 80kD), add half as much to the vial. Please note this is only a guideline and the best amount for your assay should be determined experimentally; our 3x10ug kits enable you to do this using small amounts of material and therefore at a low cost.
  2. Do I need a wash or desalt step?
    • One of the advantages of the Lightning-Link® technology compared to traditional labeling methods is that conjugate purification is not required. The Lightning-Link® reactions are highly efficient, and the kits have been optimized so that, provided the protocols are followed, there should be only a very low amount of free label left at the end of the conjugation. Any remaining free label would have its reactive 'Lightning-Link®' groups blocked by the Quencher provided in the kit, and would then be washed away during the relevant wash step of your application.
  3. Do my antibody and buffer fit the requirements?
    • Your antibody should be purified (affinity purification is preferred), as other molecules with free amine groups will interfere with the reaction, resulting in a poor quality conjugate. A suitable method of purification should be used (such as affinity or Protein A/G). Please note that 0.2/0.22 um filtration is a method of sterilization, not purification.Your biomolecule should also be in a suitable, 10-50mM amine free buffer (e.g. MES, MOPS, HEPES, PBS), pH range 6.5 to 8.5 and not in any of the following: ascites fluid, serum or tissue culture supernatant. It should not contain any additives such as Azide, BSA, Tris or Glycine at a concentration of >0.1%.The amount of antibody (IgG) you should add to the Lightning-Link® vial usually corresponds to the kit size your purchased (for example: a 3x100ug kit enable you to label 3 lots of 100ug antibody) and the volume added should also match (eg: 100ul), meaning the ideal concentration is of 1mg/ml. For other biomolecule, the amount added should be adjusted by changing your concentration (see above).NOTE: The amount and volume of antibody recommended above are for all Lightning-Link• kits offered by Innova Biosciences, with the exception of RPE and PE tandem dyes. For more details on the recommendations specific to these dyes, please consult the protocols available on each product page.
  4. How many labels will bind to my biomolecule?
    • It is difficult to give a precise answer to this as the result will vary from antibody to antibody (or other protein). Traditional labelling techniques often have F/P ratios in the range of 4-7:1, and our comparative data for staining with antibodies labelled with Lightning Link shows similar staining intensity. The ratio of dye to antibody is only ever an average for the population of labelled molecules, as individual molecules may have different amount of dye incorporated into them.
  5. How stable will my new conjugate be?
    • The Lightning-Link® chemistry joins the label to the antibody via a uni directional stable, covalent bond. The stability of your conjugate will therefore be dependent on your antibody and label of choice. In our in-house studies, conjugates made with our Lightning-Link® kits were fully active after more than 18 months' storage, undiluted, at 4 degrees C. Conjugates stored in 50% glycerol at -20 degrees C were found to be even more stable (several years). Please see below for advice on storage conditions. Please note that tandem dye stability is lower than the other dyes'. Tandem conjugates are fully stable for about 3 months at 4 degrees C.
  6. What are the best storage conditions for my new conjugate?
    • TA new conjugate can be stored for 12-18 months at 4 degrees C as long as the antibody will tolerate storage at 4 degrees C. As the bond between the antibody and dye is covalent and very stable, it should not degrade, therefore at 4 degrees C no additional preservatives are needed. The antibody is usually the least stable component of the conjugate so please check the antibody datasheet for storage recommendations. However, all conjugates can be stored in 50% glycerol at -20 degrees C which allows them to remain stable for 2 years. Please bear in mind that APC and RPE conjugates should never be stored at -20 degrees C on their own without glycerol. The dilution factor also has an effect. Storing the conjugate undiluted is recommended if possible; however, for HRP conjugates, if you wish to store at working concentrations (e.g. 1/10,000), this can be done using our LifeXtend HRP Conjugate Stabilizer/Diluent. Please note that the preservative sodium azide will inhibit HRP. We suggest that the optimal storage conditions for any conjugate are determined experimentally, using small aliquots of the conjugate.
  7. What can I do if my antibody formulation does not fit the requirements?
    • If your antibody buffer is not compatible with our kits, we have developed an AbSelect™ purification kit range that allows you to quickly and simply purify your antibody and is fully compatible with the Lightning-Link® kits.The appropriate kit to use depends on your particular sample (species, buffer, contaminants, volume,...). We have designed a handy flow chart on the AbSelect™ webpage to help you select a kit, but feel free to contact us if you require further guidance. Please consult the kit protocols to see the antibody amount/volume suitable for each kit.If your antibody is already purified but its concentration is too low, you can concentrate it by using our Antibody Concentration and Clean Up Kit. This kit can also be used to remove low molecular weight contaminants such as azide, tris or glycine by carrying out a buffer exchange into the buffer supplied in the kit, which is fully compatible with Lightning-Link®.If your antibody contains BSA, you can now use our BSA removal kit to purify your antibody in a few simple steps. Please note this kit will also enable you to concentrate your antibody.NB: All the AbSelect kits will ONLY work with antibodies. They will not purify other molecules. The only exception is the concentration and clean up kit (861-0010), which will work with other molecules greater than 10kD.
  8. What is the difference between Lightning-Link® and Lightning-Link® Rapid?
    • The benefit of the Rapid kits is that the conjugates can be generated faster because the conjugation and quenching incubation times are shorter. The antibody/protein/peptide considerations are exactly the same, as is the high quality of the final conjugate. DyLight® dyes are only available in the Rapid format.
  9. What functional groups do I need on my protein?
    • Lightning-Link Rapid requires amine groups on the molecule to be labeled. Most proteins have lysine and/or alpha-amino groups. All antibodies will have multiple amine functions.
  10. Do I need to purify the conjugate?
    • No. The chemicals used in Lightning-Link Rapid are deactivated by the Quencher, and the by-products are benign and do not need to be removed.
  11. Show All 11 FAQs.

Additional Lightning-Link (R) Rapid Cy3 Products

Blogs on Lightning-Link (R) Rapid Cy3

There are no specific blogs for Lightning-Link (R) Rapid Cy3, but you can read our latest blog posts.
Read our latest blog and use the new citation tool on bio-techne.com

Contact Information

Product PDFs

Review this Product

Be the first to review our Lightning-Link (R) Rapid Cy3 Antibody Labeling Kit and receive a gift card or discount.